| Flash-Guard® Closed Container Flash Sterilization System | |
|
 |
 |
 |
 |
| FG12-IRS |
IRS Side Angle |
FG12-WBS |
IWBS Stacked |
 |
|
FLASH-GUARD® BASKETS, RACK, & LIDS:
Instrument Basket, Stainless Steel...$295 Models: FG12-WBS, FG14-WBS, FG16-WBS, FG20-WBS.
Insert Basket, Stainless Steel......$205 Models: FG12-IWBS, FG14-IWBS, FG16-IWBS, FG20-IWBS.
Instrument Rack, Stainless Steel......$175 Models: FG12-IRS, FG14-IRS, FG16-IRS, FG20-IRS.
Lid, Stainless Steel......$115 Models: FG12-SL, FG14-SL, FG16-SL, FG20-SL.
Lid, Poly......$115 Models: FG12-PL, FG14-PL, FG20-PL.
Lid, Stainless Steel DOME Lid......$155 Model: FG20-DL. (Available in FG 20 Size Only)
| |
| FG14-WBS |
 |
| FG20-WBS |
 |
| FG20-IWBS |
 |
| FG20 Basket |
| FLASH-GUARD® ACCESSORIES |
| Universal "No Burn" Handles
 Part Number: FG-17
|
Description: Handle Replacement Part
Price: $70.00/pair |
|
| Rolling Cart for Hot Flash-Guard® Units
 Part Number: FG-Stand
|
Price: $599.00 |
|
| Autoclave Gloves
 Part Number: FG-TCAG-11
|
Description: Terry Cloth
Price: $22.50/pair | |
- FLASH-GUARD® meets gravity steam flash sterilization parameters (270°F for 3 or 10 minutes) as defined by ANSI, AAMI, AORN and sterilizer manufacturers.
-
FLASH-GUARD® is fail-safe; It has no moving parts during the sterilization process.
-
FLASH-GUARD® has no movable valves to service or check.
-
FLASH-GUARD® is made of solid stainless steel. It is so durable you may never need a replacment, and it comes with the best warranty available.
-
FLASH-GUARD® operates the same in a prevac steam sterilizer as it does in a high-speed gravity displacement (Flash) sterilizer.
-
FLASH-GUARD®’s durable stainless steel is not harmed by chemicals found in hospital steam (from boiler feed water treatment).
-
FLASH-GUARD® is failure-proof. If a sterilization failure occurs, it is always a sterilizer malfunction.
-
FLASH-GUARD® was designed with a sterilization indicator test. Flash cycle processintegrator testing devices are placed in the open Flash-Guard® exhaust port and removed and read prior to removal of the Flash-Guard® from the sterilizer. If a sterilizer failure is indicated, a different sterilizer is to be used, or the time or temperature increased to achieve a proper readout.
-
FLASH-GUARD® comes complete with a universal handle to be used to close the lid, close the exhaust port, and extract the unit onto a cart or back table.
-
FLASH-GUARD® has no valves to deteriorate or replace, and stainless steel does not degrade to a point of system failure.
|
|